vsmENC 17 - LCD Pushbutton Panel Accessory
Introduction
The vsmENC 17 can be attached to vsmLBP panels to extend their functionality.
Instead of one encoder mounted within a vsmLBP-panel, there is also the option of using one vsmENC 17 device in a 1RU 19”-housing for mounting above or below any LBP panel. A vsmENC 17 can be connected to the panel by RS422 on the rear through the RJ45-connectors of a vsmLBP panel.
Only one accessory connection per LBP panel is allowed.
Technical Specifications
Number of Encoders | 17 incremental encoder R/G/B backlight | |
Communication port | RS422 communication to LBP panel only | |
Dimension | 483mm x 43,7mm x 66,7mm (WxHxD): 1 RU | |
Weight | approx. 1,0 kg | |
Power-Consumption | < 20 W | |
Working-Environment | 0°C-50°C non condensing humidity |
Operating Conditions
The device is built to be used in a non-condensing environment within a temperature-range of 0-50°C. Under- or overshooting this working-temperature-range may cause very fast aging of the buttons or even malfunction of the whole device. Make sure not to spill any liquids e.g. coffee, coke, water... onto/into the device. The storage temperature must be within -20°C to 60°C with a maximum of 75% non-condensing relative humidity at 60°C @ 0VDC supply-voltage. Do not throw, drop or bend the device and make sure that there is no strong permanent mechanical pressure on any side at any time.
Status LEDs
LED | Color | Status | Meaning |
---|---|---|---|
1 | Orange | blinks | receiving data from LBP panel |
2 | Yellow | blinks | Blinks: transmitting data to LBP panel |
3 | Green | steady on | internal voltage OK |
Power Connector
Phoenix MC 1,5/ 4-STF-3,81
Connector for 12 V DC-supply: 4-Pin connector (MC 1,5/ 4-STF-3,81) locked with two screws, mounted on power-supplies delivered with each ENC17.
Power Supply
Product | Description | Item Number |
---|---|---|
LBP-PSU (Phoenix-Plug) | 12V DC power supply, 4-Pin-Phoenix-Type | 799-0089-000 |
(EN) Warning
It is understood that only the external Power-Supply-Unit (PSU) provided by Lawo, and shipped with the specific vsm device, is used for operating the product.
To feed the device via the DC input it is mandatory to use a 12V power source that is certified as “SELV/LPS” (if certified according to 60950) or as “ES1/PS2(LPS)” (if certified according to 62368) “NEC Class 2” 12V power source. The UL mark is valid only with use of UL certified PSUs of categories QQGQ (UL 60950) or QQJQ (UL 62368). The supplied Lawo 12V PSU is compliant to these requirements.
(F) Avertissement
Il est entendu que seul le bloc d'alimentation externe fourni par Lawo, et livré avec le dispositif vsm spécifique, est utilisé pour faire fonctionner le produit.
Pour alimenter l'appareil via l'entrée DC, il est obligatoire d'utiliser une source d'alimentation 12V conforme aux exigences «SELV / LPS» (si certifiée selon la norme IEC 60950) ou «ES1 / PS2 (LPS)» (si certifiée selon la norme IEC 62368) Source d'alimentation 12V “NEC Classe 2”. La marque UL est seulement valable quand l'alimentation elle-même est certifiée par UL dans les catégories QQGQ (norme UL 60950) ou QQJQ (norme UL 62368). Le bloc d’alimentation Lawo 12V fourni avec l’équipement est conforme à ces exigences.
Rotary Encoder for ENC 17
Each rotary-encoder is a 50-click-per-360°-rotation encoder with three R/G/B LEDs. LED colors are controlled by the corresponding key in the connected vsmLBP panel.
Serial Interface and Wiring
Connector for data drive for external accessories:
|
RS422 is a differential signal transfer. Each Tx and each Rx line has both, a negative and a positive pole, therefore it is absolutely necessary that a twisted pair cable is used. External accessory connections can easily be done by preconfigured standard shielded network cable (CAT5 or higher standard). To avoid potential difference between devices, shielded cable and shielded plugs with ground potential on both sides should be used. (Metalized plug-covers of RJ-45-plugs to touch ground-flange of RJ-45 connectors). Wrong wiring, wrong cables, wrong use of twisted pair and non-shielded traces lead to shorter working distances. Bad connection at one of the core in twisted pair traces may lead to a working unit, which seems to be working fine, but sometimes loses connection or showing strange behavior. Always use a cable-tester before installing vsmGear-products to make sure, that there will be no unsuspected trouble with connected devices. Also check proper wiring of wire-shield-traces. We suggest RS422 traces via shielded twisted pair cable not to exceed 100m (328 feet) in total length.
(EN) Warning
It is mandatory, that copper based Serial RS422-connections between LBPs and VSM accessories (e.g. vsmENC 17) are established within the same building using shielded CAT 5 or higher standard, having shielded RJ45 connectors attached.
(F) Avertissement
Il est obligatoire que les connexions série RS422 en cuivre entre les LBP et les accessoires VSM (par exemple vsmENC 17) soient établies à l'intérieur du même bâtiment en utilisant une norme CAT 5 ou supérieure, avec des connecteurs RJ45 blindés.
Getting Ready for Operation
Do the following settings in VSM Discover:
To connect an external serial vsmENC 17, please use the “Option: External Encoder” field on the corresponding LBP panel to enable this feature. A software reset is necessary for proper working external serial interface.

A powered and connected ENC 17 device will pulse blue on each encoder once, to indicate the device is ready for operation. Please define “Encoder Offset” and “Encoder LED Offset” in your vsmPanel properties.