This topic describes the "Control Interface" parameters that are used to configure the IP connection between the surface and Power Core.

The correct settings for your system will depend on the number of diamond frames that make up the surface and how you wish to connect them. All possible options are described here.

To check or edit the settings, open a Web UI connection to each device, log in as either Supervisor or Administrator, and look for the "Control Interface" parameters (in the "System → Control" tab). It is important to check both sides of the connection, so open a separate browser window for each diamond frame and Power Core.

If you make a change to the "Control Interface" settings, then you must reboot the device(s).

On Power Core...

On the Power Core side, there are four parameters: Mode, Target IP Address, Target port number and Interface.

Mode - sets the communication mode for the surface connection. There are three possible options: CAN+IP, CAN or IP.
  • The default setting is CAN+IP. In this mode, Power Core can communicate with locally connected CAN bus panels (via its CAN port) and with crystal or diamond (via Ethernet).
  • Choose CAN if there is no Ethernet connection to a surface or IP radio panel.
  • Choose IP if there is no local CAN port connection to a CAN bus panel.

Target IP Address (Uni/Multicast) - sets the IP address for the surface connection.

  • To use Multicast, the Target IP Addresses in Power Core and the surface must be identical. So, enter a suitable IP address group here and then copy it to crystal or diamond. The default setting is 239.1.1.240
  • To use Unicast, you must enter the reciprocal IP address. So, enter the surface control port IP address here.

Target Port Number - sets the port number for the surface connection. The default is 6040.

Interface - selects the network interface for the surface connection.

  • The default is dwc0.
  • To use a different interface, choose an option from the drop-down menu: dwc0, dwc1, ra0, ra1, ra2 or ra3.

On diamond...

On the diamond side, there are three parameters: Mode, Target IP Address and Target port number.

Mode - sets the communication mode of the module that sits above the frame's Ethernet connector board. There are three possible options: CAN+IP, CAN or IP.

  • The default setting is CAN+IP. In this mode, the module communicates with Power Core via Ethernet, and with all other modules in the frame via CAN. 
  • Choose CAN if there is no IP connection from the module to Power Core. (e.g. if the frame is daisy-chained to another frame via CAN).
  • Choose IP if the frame consists of a single module that communicates with Power Core via Ethernet. In this instance, there are no other modules within the frame and so there is no need for CAN.

Note that the communication modes can also be reset from the surface (as described in the next topic).

Target IP Address (Uni/Multicast) - sets the IP address for the Power Core connection.

  • To use Multicast , this must match the IP address group entered in Power Core. The default setting is 239.1.1.240
  • To use Unicast, enter the reciprocal IP address. So, enter the Power Core control port IP address here.

Target Port Number - sets the port number for the Power Core connection. The default is 6040.

Note that there is no Interface field in diamond (as there is only one Ethernet interface per connector board).

Using a Different Network Interface on Power Core

It is possible to use any of the Power Core network ports for the IP connection to the diamond surface. For simplicity, it is recommended to use dwc0.

If you wish to configure a different network interface, then work through the following steps:

  1. Start by connecting via dwc0 (to access the Power Core Web UI).
  2. From here, edit the IP settings of the port you wish to use (via the "Network Devices" tab).
  3. Then edit the Interface option (under "Control Interface" in the "System → Control" tab).
  4. Reboot Power Core and check the communication.