The Health indicator shows the health of the system. A white tick shows that everything is ok. If there is a problem, then a red exclamation mark appears.

diamond VX - Health Indicator

1.    In each case, touch the Health indicator to show more information (in the 'System Health' dialog box).

In the following example, there is a synchronization error.

diamond VX - Health OK

In the next example, the system health is ok.

diamond VX - Health Error

The individual components are named as follows:

  • Fan Main Board & Fan Slot - the four cooling fans inside Power Core. A health error is triggered by a reduction in the fan speed.
  • PSU 1 & PSU 2 - the dual power feeds to Power Core: PSU 1 = the AC input; PSU 2 = the DC input. A health error is triggered by a drop in the input voltage. 
  • Sync - the sync signal connected to Power Core. In the standard configuration, Power Core is set to operate as a PTP slave, and so a health error indicates a problem with the incoming PTP signal. The sync source can be modified by editing the configuration (using the ON-AIR Designer). For more information, see Power Core - Synchronization.
  • Temperature - the status of the temperature inside Power Core. A health error is triggered when the internal temperature exceeds 71° Celsius.

2.    Touch the X (top right) to close the 'System Health' dialog box.