The Health indicator shows the health of the system. A white tick shows that everything is ok. If there is a problem, then a red exclamation mark appears.

diamond VX - Health Indicator

1.    In each case, touch the Health indicator to show more information (in the 'System Health' dialog box).

In the following example, the system health is ok.

diamond VX - Health OK

In the next example, there is a synchronization error.

diamond VX - Health Error

The individual components are named as follows:

  • Fan Main Board & Fan Slot - the four cooling fans inside Power Core. A health error is triggered by a reduction in the fan speed.
  • PSU 1 & PSU 2 - the dual power feeds to Power Core: PSU 1 = the AC input; PSU 2 = the DC input. A health error is triggered by a drop in the input voltage. 
  • Sync - the sync signal connected to Power Core. In the standard configuration, Power Core is set to operate as a PTP slave, and so a health error indicates a problem with the incoming PTP signal. The sync source can be modified by editing the configuration (using the ON-AIR Designer). For more information, see Power Core - Synchronization.
  • Temperature - the status of the temperature inside Power Core. A health error is triggered when the internal temperature exceeds 71° Celsius.

2.    Touch the X (top right) to close the 'System Health' dialog box.