vsmTTP 10 - Touch Panel
DISCONTINUED PRODUCT
(E) Warning / (F) Avertissement
Click on the link below to read or download the booklet as a pdf.
(E) ATTENTION
DO NOT spill liquids into any system components!
DO NOT clean the front panels or operational surfaces with sharp instruments.
(F) ATTENTION
NE PAS renverser de liquides dans les composants du système!
NE PAS nettoyer les panneaux avant ou les surfaces opérationnelles avec des instruments pointus.
(E) IMPORTANT NOTE
General Cleaning / Disinfecting Requirements
Lawo hardware products are made from a variety of different materials, and each material might have specific cleaning requirements. Therefore, a general allowance for the disinfection of product surfaces with disinfectants containing alcohol cannot be given.
Our front panels and operational surfaces are not entirely approved for treatment with chemical cleaning agents and disinfectants. Component surfaces, buttons and electronics can be permanently damaged by treatment with such agents and the lifespan can be dramatically shortened. Please note that some substances can lead to discoloration of surfaces.
Lawo is not responsible for damage caused by the unauthorized use of disinfectants on our products and surfaces. Damages caused by unspecified treatment of modules and components are not covered by regular or extended warranties or SLA regulations.
This is a general instruction and recommendation for cleaning that applies to all Lawo products:
- Before cleaning the device, unplug all external power sources.
- Clean the device with a soft cloth, dipped lightly in warm to hot soapy water.
- Do not use any liquid cleaning agents or spray cleaners that may contain flammable materials.
- Do not get moisture into any openings.
- Do not use aerosol sprays, bleaches, or abrasives.
- Do not spray cleaners directly onto the item.
The above information and our technical application advice are given to the best of our knowledge.
Introduction
The vsm TTP10 has been designed as an alternative to the LBP series. In addition to touch-panel button operations, the TTP10 offers meter monitoring and the freedom of using virtual faders. The touch panel has been developed specifically for use with vsmStudio in OB vans and studios. The use of embedded components and an adapted embedded operating system guarantee a robust, maintenance-free and long-living system that meets the high requirements of mobile and stationary applications. High-quality materials and the innovative design of the panel give it both a robust and sophisticated appearance.
Features:
- Embedded system platform with adapted baseboard
- Atom N450 processor
- Capacitive touch behind a solid glass-surface
- IP54 frontally
- Small and comfortable aluminium-housing
- Foot and VESA 75 installation
Product Overview
vsmTTP10
Display | 44 rubber Buttons R/G-Backlight | |
CPU | 1xEthernet | |
OS | Windows 7 Embedded with write filter | |
Communication Port | 1 x Ethernet | |
Dimensions | 260 x 210 x 65 (WxHxD) when folded down to 0 degrees including pedestal | |
Weight | approx. 3,2KG | |
Power-Consumption | <25W | |
Working-Environment | 0°C-50°C non-condensing humidity |
Operating Conditions
This device is built to be used in a non-condensing environment within a temperature range of 0-50°C. Under or overshooting this working temperature range may cause fast aging of components or even malfunction of the whole device.
Spillage of any liquids e.g. coffee, coke, water... onto/into the device may cause damage.
The storage temperature of the device must be within -20°C to 60°C with a maximum of 75% non-condensing relative humidity at 60°C @ 0VDC supply-voltage.
DO NOT throw, drop or bend the unit and make sure that there is no strong permanent mechanical pressure on any side of the housing at any time.
Before installing or using this device, always read and observe the Important Safety Instructions.
Preparing for Operation
The TTP10 has an active write filter so it won't store any changes of the OS or the applications except for when the device receives a reset command via vsmDiscover. Due to this please apply all needed settings first and then use the "Reset" button in vsmDiscover to write the changes to the non-volatile memory. If the device loses power before a vsmDiscover reset command has been sent, it will also lose all changes that have been made since last start.
All Lawo vsm devices will be shipped with DHCP enabled network configuration. If you don't have a DHCP network ask your administrator for static network settings and edit the "Network" section if required.
Do the following settings in VSM Discover:
To connect the device to a vsmStudio, edit Server 1 – 4 and the Panel ID in the "Application" section.
The Location and Comment fields in the "Misc" section are to easily allocate the device in your environment.
Press "Apply" button if you are sure you have entered the settings correctly. Perform a reboot with the "Reset" button to store the configuration to the non-volatile memory.
Technical Specifications
Connectors
Power
Alternative connector (desktop panels only) for 12 V DC supply: 4-pin Hirose HR10A-7P-4P locked bayonet joint compact connector for better cable traction relief, mounted on power-supplies delivered with each vsmTTP10 panel.
Pin | Signal | |
1 | GND | |
2 | GND | |
3 | + | |
4 | + |
Power Supply
Product | Description | Item Number |
---|---|---|
LBP-DT-PSU (Hirose-Plug) | 12V DC power supply, 4-Pin-Phoenix-Type | 799-0090-000 |
(EN) Warning
Important: It is understood that only the external Power-Supply-Unit (PSU) provided by Lawo, and shipped with the specific vsm device, is used for operating the product.
To feed the device via the DC input it is mandatory to use a 12V power source that is certified as “SELV/LPS” (if certified according to 60950) or as “ES1/PS2(LPS)” (if certified according to 62368) “NEC Class 2” 12V power source. The UL mark is valid only with use of UL certified PSUs of categories QQGQ (UL 60950) or QQJQ (UL 62368). The supplied Lawo 12V PSU is compliant to these requirements.
(F) Avertissement
Important: Il est entendu que seul le bloc d'alimentation externe fourni par Lawo, et livré avec le dispositif vsm spécifique, est utilisé pour faire fonctionner le produit.
Pour alimenter l'appareil via l'entrée DC, il est obligatoire d'utiliser une source d'alimentation 12V conforme aux exigences «SELV / LPS» (si certifiée selon la norme IEC 60950) ou «ES1 / PS2 (LPS)» (si certifiée selon la norme IEC 62368) Source d'alimentation 12V “NEC Classe 2”. La marque UL est seulement valable quand l'alimentation elle-même est certifiée par UL dans les catégories QQGQ (norme UL 60950) ou QQJQ (norme UL 62368). Le bloc d’alimentation Lawo 12V fourni avec l’équipement est conforme à ces exigences.
Ethernet
Ethernet Communication Port to vsmStudio
(EN) Information
This interface is used as the ethernet communication port to vsmStudio.Port de communication Ethernet vers vsmStudio
(F) Information
Cette interface est utilisée comme port de communication Ethernet vers vsmStudio.
Pin | Signal | Color of a standard TIA-568A-shielded twisted pair patch cable (CAT5 or higher) | Scheme |
---|---|---|---|
1 | TX+ | white/green | |
2 | TX- | green | |
3 | RX+ | white/orange | |
4 | NC* | blue | |
5 | NC* | white/blue | |
6 | RX- | orange | |
7 | NC* | white/brown | |
8 | NC* | brown |
Notice for Wiring:
- NC: no connection; do not connect to any signal or supply
- Only use shielded CAT5 (or higher standard) -specified networkable. Refer to TIA-568A or TIA-568B for wiring.
- Do not use cable-traces longer than 100m (328ft) between the device and network-switch for 100BASE-T communication.
- Make sure to keep to wiring standards and use shielded RJ45-plugs for shielded cable on both ends of the line.
(EN) Warning
It is mandatory, that copper based Ethernet connections (CAT 5, or higher standard RJ45) are led inside a building to the third party-device-ethernet-switch . If the Ethernet connection needs to be led outside a building it is mandatory to use a optical fiber. Use a converter to optical fiber and connect it in a short way (inside the building) to the device.
(F) Avertissement
Il est obligatoire que les connexions Ethernet à base de cuivre (CAT 5 ou une norme supérieure, RJ45) soient installées à l'intérieur d'un bâtiment jusqu'au prochain switch Ethernet. Si la connexion Ethernet doit être dirigée à l'extérieur d'un bâtiment, utilisez un convertisseur en fibre optique et une connexion courte (à l'intérieur du bâtiment) à l'appareil.