DISCONTINUED PRODUCT

Final compatible vsmStudio version is B2149 (Release 16.1.3 [Patch])

(E) Warning / (F) Avertissement

When working with our hardware components, please read and observe all of the instructions provided in the "General Safety Information for Lawo Equipment" booklet delivered with your devices.

Click on the link below to read or download the booklet as a pdf.

Before cleaning VSM hardware components, please read and observe all of the following instructions.

Before cleaning your Lawo devices, please read and observe all of the following instructions.


(E) ATTENTION

DO NOT spill liquids into any system components!

DO NOT clean the front panels or operational surfaces with sharp instruments.

(F) ATTENTION

NE PAS renverser de liquides dans les composants du système!

NE PAS nettoyer les panneaux avant ou les surfaces opérationnelles avec des instruments pointus.

(E) IMPORTANT NOTE

General Cleaning / Disinfecting Requirements

Lawo hardware products are made from a variety of different materials, and each material might have specific cleaning requirements. Therefore, a general allowance for the disinfection of product surfaces with disinfectants containing alcohol cannot be given.

Our front panels and operational surfaces are not entirely approved for treatment with chemical cleaning agents and disinfectants. Component surfaces, buttons and electronics can be permanently damaged by treatment with such agents and the lifespan can be dramatically shortened. Please note that some substances can lead to discoloration of surfaces.

Lawo is not responsible for damage caused by the unauthorized use of disinfectants on our products and surfaces. Damages caused by unspecified treatment of modules and components are not covered by regular or extended warranties or SLA regulations.

This is a general instruction and recommendation for cleaning that applies to all Lawo products:

  • Before cleaning the device, unplug all external power sources.
  • Clean the device with a soft cloth, dipped lightly in warm to hot soapy water.
  • Do not use any liquid cleaning agents or spray cleaners that may contain flammable materials.
  • Do not get moisture into any openings.
  • Do not use aerosol sprays, bleaches, or abrasives.
  • Do not spray cleaners directly onto the item.

The above information and our technical application advice are given to the best of our knowledge.

Introduction

The Lawo Push-Button Panel (PBP) series is a cost-efficient line of push-button panels that may be used in conjunction with a vsmStudio control system.

Features:

  • Software configurable buttons.
  • Each button capable of performing single or multiple functions simultaneously.
  • Each panel can be configured as "single destination", "multiple destinations", "XY" panel or any combination of these variations.
  • Every PBP has two low power GPIs and GPOs.
  • Every PBP is equipped with Ethernet interface.
  • Button functions include: select sources or targets, GPI control, parameter control, macros, go-to, take, lock, enable, escape, shift and many more.
  • R/G backlight at the PBP's allows the choice of multiple colours for button illumination.

Product Overview

vsmPBP 44

Number of buttons

44 rubber Buttons R/G-Backlight

Communication port

1xEthernet

Dimensions

483mm x 43,7mm x 41,6mm (WxHxD):1RU

Weight

approx. 0,7KG

Power-Consumption

<20W

Working-Environment

0°C-50°C non-condensing humidity

Operating Conditions

This device is built to be used in a non-condensing environment within a temperature range of 0-50°C. Under or overshooting this working temperature range may cause fast aging of components or even malfunction of the whole device.

Spillage of any liquids e.g. coffee, coke, water... onto/into the device may cause damage.

The storage temperature of the device must be within -20°C to 60°C with a maximum of 75% non-condensing relative humidity at 60°C @ 0VDC supply-voltage.

DO NOT throw, drop or bend the unit and make sure that there is no strong permanent mechanical pressure on any side of the housing at any time.

Before installing or using this device, always read and observe the Important Safety Instructions.

Preparing Panels for Operation

If the device has no physical link to the network, button 1 and 23 will blink fast alternately red. If link is established, blink frequency is reduced by half and the button will blink in yellow color.
All Lawo vsm devices will be shipped with DHCP enabled network configuration. If you don't have a DHCP network ask your administrator for static network settings and edit the "Network" section if required.

Do the following settings in VSM Discover:

Press the "Apply" button in vsmDiscover if you are sure you have entered the settings correctly. The device will automatically perform a reboot to apply the network configuration. To connect the device to vsmStudio (Server 1 – 4 depending on level of redundancy) and to assign Panel IDs go to the "Application" section. Button brightness is only controllable over the "Brightness" field in vsmDiscover.

The Location and Comment fields in the "Misc" section are to easily allocate the device in your environment.

Additional read-only status and device information from vsmDiscover:


Technical Specifications

Status LEDs

Rear-view

LEDColorStatusMeaning
1RGBBlue, Steady on

internal serial I/O controller OK,

green: serial TX,

red: serial RX.

2RGBRed Pulseno connection to the network
Red Fast Blinkdevice in bootloader-mode
Yellow Pulsenetwork connection established
Blue Pulseconnected to vsmStudio
3GreenSteady onprocessor core-voltage OK
4GreenSteady oninternal I/O-voltage OK
5OrangeBlinkphysical LAN connection / TCP/IP-data-transfer

Buttons

Each PBP pushbutton has a button size of 12mm x 12mm. The backlight colour is R/G, so three colours can be displayed in different colour gradation.

The key stroke of the tactile buttons is about 2.0mm +/-0.1mm using an operation force of approximately 2.0N +/-0.8N. Button-spacing of PBP-panel is (X x Y) 19,05mm x 21,0mm.

Connectors

Power

Connector for DC-supply: 4-Pin connector (MC 1,5/ 4-STF-3,81) locked with two screws.


Power Supply

ProductDescriptionItem Number
LBP-PSU (Phoenix-Plug)12V DC power supply, 4-Pin-Phoenix-Type799-0089-000


(EN) Warning

ImportantIt is understood that only the external Power-Supply-Unit (PSU) provided by Lawo, and shipped with the specific vsm device, is used for operating the product.

To feed the device via the DC input it is mandatory to use a 12V power source that is certified as “SELV/LPS” (if certified according to 60950) or as “ES1/PS2(LPS)” (if certified according to 62368) “NEC Class 2” 12V power source. The UL mark is valid only with use of UL certified PSUs of categories QQGQ (UL 60950) or QQJQ (UL 62368). The supplied Lawo 12V PSU is compliant to these requirements.

(F) Avertissement

ImportantIl est entendu que seul le bloc d'alimentation externe fourni par Lawo, et livré avec le dispositif vsm spécifique, est utilisé pour faire fonctionner le produit.

Pour alimenter l'appareil via l'entrée DC, il est obligatoire d'utiliser une source d'alimentation 12V conforme aux exigences «SELV / LPS» (si certifiée selon la norme IEC 60950) ou «ES1 / PS2 (LPS)» (si certifiée selon la norme IEC 62368) Source d'alimentation 12V “NEC Classe 2”. La marque UL est seulement valable quand l'alimentation elle-même est certifiée par UL dans les catégories QQGQ (norme UL 60950) ou QQJQ (norme UL 62368).  Le bloc d’alimentation Lawo 12V fourni avec l’équipement est conforme à ces exigences.

GPI/O Interface - Connector

Connector for rear GPI/O interface: 8-Pin connector locked with two screws (MC 1,5/ 8-STF-3,81)

Separate plug not included for standard PBP delivery.
Each PBP panel features two dry relays-outputs and 2 opto-coupled TTL-inputs.

O2-O1-I2-I1-

Dry Relay

Dry Relay

Input/GND [0...5 VDC]

Input/GND [0...5 VDC]

Out No. 2Out No. 1In No. 2In No. 1

The built-in GPI inputs follow PS1 (electrical power source class1).
The GPI input will not allow power to exceed 1W by the device itself.

  • Open circuit voltage GPI input: approx. 3,8V DC, max. 5V DC
  • Short circuit current GPI input: approx. 8mA
  • Loaded circuit current with externally 5V (PS1) supplied: approx. 12mA


GPI - General Purpose Input:

(EN) Information

This Interface is a small signal interface only,  and uses same ground potential.

The GPI DC TTL Inputs are able to “set” a readable input by either shorting the input to ground, or by supplying any 5 VDC-voltage and undershooting 2,3 VDC respective to ground.
We suggest using the separate stand-alone vsmGPIO-unit for switching higher current or reading inputs up to 12VDC.

(EN) Warning

It is understood that if supplying any external voltage (DC only) to the GPI input, it is never to exceed 5V DC rms and must also follow the PS1-rules (b-IEC 62368-1) to never source more than 15W. Check polarity if external voltage is supplied.
Always connect GPI input-ground to external supply-ground! Never apply any AC-voltage to the GPI inputs!

(F) Information

Cette interface n'est qu'une interface basse tension, faible courant.

Les entrées GPI DC TTL sont capables de "régler" une entrée lisible soit en court-circuitant l'entrée à la terre, soit en fournissant une tension de 5 V DC et une sous-tension de 2,3 V DC respectivement à la terre.
Nous suggérons d'utiliser l'unité autonome séparée vsmGPIO pour commuter un courant plus élevé ou lire des entrées jusqu'à 12 V DC.

(F) Avertissement

Il est entendu que si une tension externe (DC uniquement) est fournie à l'entrée GPI, elle ne doit jamais dépasser 5V DC rms (valeur efficace) et doit également suivre les règles PS1 (norme b-IEC 62368-1) pour ne jamais fournir plus de 15W. Vérifiez la polarité si une tension externe est fournie.
Toujours connecter la masse de l'entrée GPI à la masse de l'alimentation externe ! Ne jamais appliquer de tension AC aux entrées GPI !

Possible GPI Input wiring and control options

GPO - General Purpose Output:

(EN) Information

The GPO "outputs" are dry relay contacs. They are internally not connected to any supply or ground. The user has to provide an external power source that follow the PS1-rules (b-IEC 62368-1) for usage.

(EN) Warning

To maintain the lifespan of the internal relay of the PBP, do not exceed 12VDC/50mA for each relay-contact.

The external supply-source beeing used for interfacing the PBP relay-contacts must also follow the PS1-rules (b-IEC 62368-1) to never source more than 15W.


(F) Information

Les GPO « sorties » sont des contacts de relais secs. Ils ne sont connectés en interne à aucune alimentation ou terre. L’utilisateur doit fournir une source d’alimentation externe qui suit les règles PS1 (norme b-IEC 62368-1) pour l’utilisation.

(F) Avertissement

Pour prolonger la durée de vie du relais interne du PBP, ne dépassez pas 12VDC/50mA pour chaque sortie relais.

L’alimentation externe utilisée pour l’interfaçage des contacts relais PBP doit également suivre les règles PS1 (norme b-IEC 62368-1) pour ne jamais s’approvisionner plus de 15W.

GPO contact-wiring “dry relay output”

External Serial Interface

Connector for data drive for external accessories:

  • 1 x RS422 via RJ45 connector
  • 1 x RS422 (loop through) via RJ45 connector
  • Serial Baud Rate will be configured automatically by the device to 115200 Baud.

RS422 is a differential signal transfer. Each Tx and each Rx line has both, therefore it is absolutely necessary that a twisted pair cable is used. External accessory connections can easily be done by preconfigured standard shielded network cable (CAT5 or higher standard). To avoid potential difference between devices, shielded cable and shielded plugs with ground potential on both sides should be used. (Metalized plug-covers of RJ-45-plugs to touch ground-flange of RJ-45 connectors). Wrong wiring, wrong cables, wrong use of twisted pair and non-shielded traces lead to short working distances. Bad connection at one of the cores using twisted pair traces may lead to a working unit, which seems to be working fine, but sometimes loses connection or shows strange behaviour. Always use a cable-tester before installing vsmGear products to ensure that there will be no unsuspected connection issues with connected devices. Also check correct wiring of wire-shield-traces. We suggest RS422 traces via shielded twisted pair cable not to exceed 100m (328 feet) in total length.

Ethernet

Ethernet Communication Port to vsmStudio

(EN) Information

This interface is used as the ethernet communication port to vsmStudio. It is understood that for proper operation each PBP panel is connected to an Ethernet-switch where the individual port of the switch must be set to “Auto-Negotiation”.

Port de communication Ethernet vers vsmStudio

(F) Information

Cette interface est utilisée comme port de communication Ethernet vers vsmStudio. Il est entendu que pour un fonctionnement correct, chaque LBP est connectée à un switch Ethernet dont le port individuel est réglé sur "Auto-négociation".

PinSignal

Color of a standard TIA-568A-shielded

twisted pair patch cable (CAT5 or higher)
Scheme
1TX+white/green

2TX-green
3RX+white/orange
4NC*blue
5NC*white/blue
6RX-orange
7NC*white/brown
8NC*brown

Notice for Wiring:

  • NC: no connection; do not connect to any signal or supply
  • Only use shielded CAT5 (or higher standard) -specified networkable. Refer to TIA-568A or TIA-568B for wiring.
  • Do not use cable-traces longer than 100m (328ft) between the device and network-switch for 100BASE-T communication.
  • Make sure to keep to wiring standards and use shielded RJ45-plugs for shielded cable on both ends of the line.



(EN) Warning

It is mandatory, that copper based Ethernet connections (CAT 5 or higher standard, RJ45) are led inside a building to the third party-device-ethernet-switch . If the Ethernet connection needs to be led outside a building it is mandatory to use a optical fiber. Use a converter to optical fiber and connect it in a short way (inside the building) to the device.

(F) Avertissement

Il est obligatoire que les connexions Ethernet à base de cuivre (CAT 5 ou une norme supérieure, RJ45) soient installées à l'intérieur d'un bâtiment jusqu'au prochain switch Ethernet. Si la connexion Ethernet doit être dirigée à l'extérieur d'un bâtiment, utilisez un convertisseur en fibre optique et une connexion courte (à l'intérieur du bâtiment) à l'appareil.