Configure the GXP880Link to Configure the GXP880

Open the Axon Cortex Software and select your Frame. Select the GXP880 (1) and configure the network settings (2).

Configure vsmStudioLink to Configure vsmStudio

Create ConnectionLink to Create Connection

Create a x-Switch connection over pro-bel SW-P-08 (1) to the IP-Address of the GXP880 with Port 7800.


Create a new port and enter a description (1). Enter the IP-Address of your GXP880 (2) and enter port 7800 (3).


Add the respective vsmStudio matrix layer to the connection (1).

Technical NotesLink to Technical Notes

  • The switch-port to which the axon frame is connected, may need to be switched to 10Mbit/s half duplex.
  • The GXP880 accepts only one connection at any time.


Supported based on Firmware 0604 is:

  • crosspoint switching is working and reported back.
  • on connection actual crosspoints aren’t reported.