TVLogic ExternalControl
Content
Summary
This document provides information about the TVLogic External Control protocol implementation for VSM.
Status of Driver | APPROVED |
---|---|
Component for Driver | GADGETSERVER |
Release (Build) of Component | vsmGadgetserver 5.4.x (2016) |
Revision of Implementation | 1.0 |
Name/Type of 3rd Party API | |
---|---|
Version of 3rd Party API | |
Additional 3rd Party information | Tested with
|
Connection
Connection Type | Serial RS485 |
---|---|
Default Port | Setting: 19200/N/8/1 Connected via SmartHub |
The connection between smarthub and first device needs a specially configured cable. The connection between the devices needs a cable with 1:1 configuration.
Pin No. | SmartHub | Device |
---|---|---|
1 | TXD+ | |
2 | TXD- | |
3 | RXD+ | RXD+ |
4 | TXD+ | |
5 | TXD- | |
6 | RXD- | RXD- |
7 | ||
8 | GND |
Supported Features
- Input Select
Supported Commands
Command 1 | Input Set |
---|---|
Command 2 | Request Status |
Available Sources and their internal value:
Source | Enum Value |
---|---|
SDI A | 0 |
SDI B | 1 |
1.1 QUAD | 10 |
Composite 1 | 20 |
Composite 2 | 21 |
Composite 3 | 22 |
S Video | 23 |
Component | 24 |
RGB | 25 |
VGA | 26 |
Digital | 27 |
HDMI | 28 |
Configuration Details
The protocol requires the following obligatory configuration:
Device Identifier (0 - 99). The default is set to “1”.
Known Issues