diamond VX - Initial Settings
The "Emberdefault.ini" file stores the initial settings for the diamond VX app. The settings load whenever the diamond VX app starts. This allows you to customize the operation by editing and saving the file, and then restarting the app.
After a standard install, the file is located at: C:\ProgramData\DSA
You can use any suitable text editor to edit the file.
The example below shows how to define the bookmarks on the 'Browser' page.
The tables below describe the available parameters.
Boolean Parameters
The following parameters can be set to a boolean value: either true or false.
Name | Description | Default | Additional Information |
---|---|---|---|
gpio/Boolean 1 | Top Bar - Show Clock | true | - |
gpio/Boolean 2 | Top Bar - Show Mic Timer | true | - |
gpio/Boolean 3 | Top Bar - Show Notifications | false | - |
gpio/Boolean 4 to 14 | - | - | - |
gpio/Boolean 15 | Combo Module Setup | false | setup independent |
gpio/Boolean 16 | Swap Slot position | false | - |
String Parameters
The following parameters can be used to enter a text string. For example, to define the 'Browser Page' bookmark URLs and labels.
Name | Description | Default | Additional Information |
---|---|---|---|
gpio/String 1 | Bookmark 01 URL | - | - |
gpio/String 2 | Bookmark 01 Label | - | - |
gpio/String 3 | Bookmark 02 URL | - | - |
gpio/String 4 | Bookmark 02 Label | - | - |
gpio/String 5 | Bookmark 03 URL | - | - |
gpio/String 6 | Bookmark 03 Label | - | - |
gpio/String 7 | Bookmark 04 URL | - | - |
gpio/String 8 | Bookmark 04 Label | - | - |
gpio/String 9 | Bookmark 05 URL | - | - |
gpio/String 10 | Bookmark 05 Label | - | - |
gpio/String 11 | Bookmark 06 URL | - | - |
gpio/String 12 | Bookmark 06 Label | - | - |
gpio/String 13 | Bookmark 07 URL | - | - |
gpio/String 14 | Bookmark 07 Label | - | - |
gpio/String 15 | Bookmark 08 URL | - | - |
gpio/String 16 | Bookmark 08 Label | - | - |
gpio/String 17 to 20 | - | - | - |
gpio/String 21 | default URL Playout Session 01 | - | - |
gpio/String 22 | default URL Playout Session 02 | - | - |
gpio/String 22 | default URL Playout Session 03 | - | - |
gpio/String 24 | default URL Playout Session 04 | - | - |
gpio/String 25 | Default PPM View in Channel Overview | 01 | 01 = PPM 02 = LU 03 = PPM + LU |
gpio/String 26 | Sync between Sessions for PPM View | !! NO DEFAULT | this information is written in the session to sync Sessions. Not available for changes! |
gpio/String 27 | Topbar Line 01 | diamond | |
gpio/String 28 | Topbar Line 02 | Broadcast Console | |
gpio/String 29 | Default Slot 01 | 01 | PGM 1 Meter |
gpio/String 30 | Default Slot 02 | 02 | PGM 2 Meter |
gpio/String 31 | Default Slot 03 | 05 | CR Meter |
gpio/String 32 | Default Slot 04 | 06 | HP Meter |
gpio/String 33 to 39 | - | - | - |
gpio/String 40 | I/O Information for Routing Page Slot 01 | !! NO DEFAULT | this information is written to the routing page of other sessions. Not available for changes! |
gpio/String 41 | I/O Information for Routing Page Slot 02 | !! NO DEFAULT | " |
gpio/String 42 | I/O Information for Routing Page Slot 03 | !! NO DEFAULT | " |
gpio/String 43 | I/O Information for Routing Page Slot 04 | !! NO DEFAULT | " |
gpio/String 44 | I/O Information for Routing Page Slot 05 | !! NO DEFAULT | " |
gpio/String 45 | I/O Information for Routing Page Slot 06 | !! NO DEFAULT | " |
gpio/String 46 | I/O Information for Routing Page Slot 07 | !! NO DEFAULT | " |
gpio/String 47 | I/O Information for Routing Page Slot 08 | !! NO DEFAULT | " |
gpio/String 48 to 64 | - | - | - |