Each frame is powered by an external DC power supply (954/99). The PSU comes with an IEC power cable that is country-specific. For frame widths of 5 ME or above, a second power supply and IEC power cable are provided.

If the Virtual Extension is included, then each VX display also requires an external DC power supply (SP4851209). This is different from the frame's supply, so take care not to mix up the part numbers (if you need to order a replacement power supply).

PSU TypePart Number
12V DC Power Supply for a diamond frame954/99
12V DC Power Supply for a diamond VX moduleSP4851209

Ordering Information

For a new system, the power supplies are included with the frame(s). To order a spare part, please use the part numbers listed above.

Specifications

For dimensions, weight and electrical specifications, please refer to the data sheets for the power supplies. These are available from the Lawo Download-Center (after login).

IEC Power Cables

Each external DC power supply is delivered with an IEC power cable that is country-specific. The table below describes all permitted options.


NamePart NumberDescription

IEC Lock Schuko

436-7206-000

Power Cord with European connector for e.g. D, AU, F, Benelux.

IEC Lock Open Ends

436-7207-000

Power Cord with open wire ends.

IEC Lock US

436-7208-000

Power Cord with connector for USA.

IEC Lock UK

436-7209-000

Power Cord with connector for United Kingdom.

IEC Lock AUS

436-7218-000

Power Cord with connector for Australia.

IEC Lock JPN

436-7219-000

Power Cord with connector for Japan.

Using the DC Power Supplies

Before connecting power to a diamond frame, please read and observe all of the instructions in the "General Safety Information for Lawo Equipment" booklet delivered with your devices.


(E) WARNING

The AC input(s) MUST be connected to the mains using the power cable(s) supplied with the system. 

Disconnect all power sources to completely disconnect power from the system. e.g. before you open the unit for maintenance and service.

Take care that the protective earth (PE) connection of each PSU is individually connected to the PE connection of the building installation (e.g. wall socket). It is forbidden to use IEC Y-cables, or connect both PSUs to the same multiple-socket outlet. This measure guarantees that there is no shared PE connection (whose failure would lead to a summation of the leakage current from both PSUs to the housing).

(F) AVERTISSEMENT

La ou les entrées CA DOIVENT être connectées au secteur à l'aide du ou des câbles d'alimentation fournis avec le système.

Déconnectez toutes les sources d'alimentation pour couper complètement l'alimentation du système, par exemple avant d'ouvrir l'unité pour la maintenance et l'entretien.

Veillez à ce que la connexion de terre de protection (PE) de chaque PSU soit connectée individuellement à la connexion PE de l'installation du bâtiment (par exemple, une prise murale). Il est interdit d'utiliser des câbles en Y IEC, ou de connecter les deux PSU à la même prise multiple. Cette mesure garantit qu'il n'y a pas de connexion PE partagée (dont la défaillance entraînerait une sommation du courant de fuite des deux PSU vers le boîtier).

For each diamond frame, the DC input is located on the connector board (on the underside of the frame).

Cabling instructions:

  1. Connect the frame's external DC power supply to the 12V IN on the connector panel.
  2. Using the IEC cable provided, connect your AC mains to the PSU.
  3. If the frame includes more than one connector panel, then repeat the steps to apply power to each section of the frame.
  4. If the Virtual Extension is included, then repeat the steps to apply power to each of the VX displays.

The surface and VX modules have no on/off switch and start automatically when power is applied. What happens next is described later. See Powering On & Starting the GUI.