There have been three revisions of Power Core since its first introduction. The table below summarizes the main differences. Power Core RP v2 can be ordered in either of the current revisions (2 and 3).
Power Core Frame | Type Number | Summary of differences |
---|
Revision 3, Current
| 710/13
| Changes from revision 2: - Added 2 x RAVENNA/AES67 interfaces (ra2, ra3). This doubles the maximum number of streams/AoIP channels.
- Easy access to SD card (from front) for data backup/exchange.
- New USB type B server port (at front) for diagnostics.
- Removed GPIO (from front) to make way for new features. GPIOs can be added via rear expansion I/O cards.
|
Revision 2, Current
| 710/11 | Changes from revision 1: - All network interfaces changed from RJ45 to SFPs, to support a range of cable types and connectors.
- Added 1 x network control interface (dwc1).
|
Revision 1, Discontinued
| 710/10 | First release. - 1 x network control interface (dwc0).
- 2 x RAVENNA/AES67 interfaces (ra0, ra1).
- All network interfaces available via RJ45.
- GPIO included (at front).
|